Aadhunik Industries is a manufacturing group company. Aadhunik Industries is pioneer manufacturers of Specialty Chemicals, Pharmaceutical Excipients, Food Fragrance & Flavor chemicals in India. It has toll manufacturers and representatives in UAE, Europe, Canada & USA and agents & customers in all countries like USA, Canada, Europe, UAE Dubai, South Africa, Tanzania, Kenya, Egypt, Nigeria, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Malaysia, Indonesia, Thailand, Korea, Japan, etc. Halal & Kosher certified Calcium Iodide Manufacturers made in a FDA-GMP-GLP plant is offered. The units have one or more of the certifications like FDA GMP, ISO 9001, ISO 22000, HACCP, REACH, Kosher & Halal and DMF support is available.
![]()
![]()
![]()
Calcium Iodide SDS MSDS Sheet of Manufacturers
Specifications of Calcium Iodide Manufacturers
Calcium Iodide SDS MSDS Sheet, Material Safety Data Sheet
Section 1 - Chemical Product and Identification
MSDS Name: Calcium Iodide
Chemical Formula: CaI2
Molecular Weight: 293.9
CAS Number: 10102-68-8
EINECS EC Code: 233-276-8
Intended use: Laboratory Chemicals and Industrial Manufacturing Use.
Supplier: As per letterhead.Section 2 - Hazards Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.Labeling according GHS & Regulation (EC) No 1272/2008
GHS Label Elements
NONESignal Word: None
Hazards not otherwise classified (HNOC):
May causes mild skin irritation.
May causes mild eye irritation.Precautionary statements:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P262: Do not get in eyes, on skin, or on clothing.
P281: Use personal protective equipment as required.
P302+P352 - IF ON SKIN: Wash with plenty of soap and water.
P303+P361+P353 - IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P304 + P340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337+313: If eye irritation persists get medical advice/attention.
Section 3 - Composition, Information on Ingredients
Product: Calcium Iodide
CAS Number: 10102-68-8
EINECS EC Code: 233-276-8
Percent:: 100Section 4 - First Aid Measures
Always seek medical advice after the first aid treatment.
Eyes: Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid.
Skin: Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Get medical aid if irritation develops or persists. Wash clothing before reuse.
Ingestion: If victim is conscious and alert, give 2-4 cupfuls of milk or water. Get medical aid. Wash mouth out with water.
Inhalation: Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid if cough or other symptoms appear.
Notes to Physician: NoneSection 5 - Fire Fighting Measures
General Information: Water runoff can cause environmental damage. Dike and collect water used to fight fire. Wear appropriate protective clothing to prevent contact with skin and eyes. Wear a self-contained breathing apparatus (SCBA) to prevent contact with thermal decomposition products. Substance is noncombustible.
Extinguishing Media: For small fires, use water spray, dry chemical, carbon dioxide or chemical foam.
Special hazards arising from the substance: Hydrogen iodide, Calcium oxidesSection 6 - Accidental Release Measures
General Information: Use proper personal protective equipment.
Spills/Leaks: Vacuum or sweep up material and place into a suitable disposal container. Clean up spills immediately, observing precautions in the Protective Equipment section. Avoid generating dusty conditions. Provide ventilation.Section 7 - Handling and Storage
Handling: Use with adequate ventilation. Minimize dust generation and accumulation. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Do not ingest or inhale.
Storage: Store in a cool, dry, well-ventilated area away from incompatible substances. Store protected from moisture.Section 8 - Exposure Controls, Personal Protection
Engineering Controls: Good general ventilation should be sufficient to control airborne levels. Facilities storing or utilizing the material should be equipped with an eyewash facility and a safety shower.
Exposure Limits: Not listed by ACGIH NIOSH & OSHA-Final PELs.
Personal Protective Equipment
Eyes: Wear safety glasses with side shields.
Skin: Wear appropriate gloves to prevent skin exposure.
Clothing: Wear appropriate protective clothing to minimize contact with skin.
Respirators: A NIOSH/MSHA approved air purifying dust or mist respirator or European Standard EN 149.Section 9 - Physical and Chemical Properties
Physical State: Solid
Appearance: Yellowish to Redddish
Odor: Odorless
pH: Not available.
Vapor Pressure: Not available.
Vapor Density: Not available.
Evaporation Rate: Not available.
Viscosity: Not available.
Boiling Point: 1100 deg C
Melting Point: 779 deg C
Decomposition Temperature: Not available
Explosion Limits: Not available.
Solubility: Soluble in water.
Specific Gravity/Density: 3.96
Chemical Formula: CaI2
Molecular Weight: 293.9Section 10 - Stability and Reactivity
Chemical Stability: Stable.
Conditions to Avoid: High temperatures, exposure to moist air or water Strong acids, Strong oxidizing agents.
Hazardous Decomposition Products: Toxic fumes of iodine or hydrogen iodide and calcium oxide.
Hazardous Polymerization: Has not been reported.Section 11 - Toxicological Information
LD50 Oral - Rat - Not available
Carcinogenicity: Not listed by ACGIH, IARC, NIOSH, NTP, or OSHA.
Epidemiology: No information reported.
Teratogenic: No information reported.
Neurotoxicity: No information reportedSection 12 - Ecological Information
Toxicity to fish: LC50 - No information reported.
Environmental: No information reported.
Results of PBT and vPvB assessment: No information reported.Section 13 - Disposal Considerations
Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. US EPA guidelines for the classification determination are listed in 40 CFR Parts 261.3. Additionally, waste generators must consult state and local hazardous waste regulations to ensure complete and accurate classification.
Section 14 - Transport Information
DOT (US): Not dangerous goods
IMDG: Not dangerous goods
IATA: Not dangerous goods
ADR/RID: Not dangerous goodsSection 15 - Regulatory Information
USA Regulations:
SARA 302 Components: Not listed.
SARA 313 Components: Not listed.
SARA 311/312 Hazards: No SARA Hazards
California Prop. 65 Components: Not listed.Section 16 - Additional Information
DISCLAIMER: The information and recommendations set forth herein (hereinafter "Information") are presented in good faith and believed correct as of the date hereof. It is compiled from various sources and it is not necessarily all inclusive nor fully adequate in every circumstance. In addition, these suggestions should not be confused with nor followed in violation of applicable laws, regulations, rules or insurance requirements applicable. This MSDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a particular purpose.Calcium Iodide Pure and Reagent Grade Manufacturers
Aadhunik Industries
Ankleshwar Gujarat &, Mumbai, India
TEL: (OFFICE) 91-22-23774610, 23723564.e-mail: info@aadhunikindustries.com
Exports to USA, Canada, UAE, Dubai, South Africa, Tanzania, Kenya, Nigeria, Egypt, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Europe Netherlands, Italy, Spain, Germany, Portugal, France, Malaysia, Indonesia, Thailand, Vietnam, Korea, Japan, etc. ok
Copyright and Usual Disclaimer is Applicable January 20, 2022